Pipes
Underfloor heating pipes are the part of the system that remains permanently built into the floor construction. Once the screed has been laid, access to them is severely limited, so the material, the size and the correct sizing of the circuits are especially important.
Here you will find PE-Xb underfloor heating pipes with an oxygen barrier in sizes 16x2 mm and 20x2 mm.
Read more
What is a PE-Xb pipe?
PE-X is cross-linked polyethylene. The letter after the designation indicates the method by which the material was cross-linked.
More important when choosing is that the pipe is intended for heating systems and meets the required operating parameters.
The pipes we offer also specify an oxygen barrier. Its task is to limit the penetration of oxygen through the pipe wall into the heating water, which is important for protecting the metal elements in the system.
A 16x2 or 20x2 pipe?
The size 16x2 means an outside diameter of 16 mm and a wall thickness of 2 mm. Likewise, with 20x2 the outside diameter is 20 mm.
We do not recommend choosing on the logic that “the larger pipe is better”.
- 16x2 mm – a smaller outside diameter and different requirements for the fittings and the hydraulics;
- 20x2 mm – a larger inside diameter, which affects the flow rate, the hydraulic resistance and the sizing of the circuit.
The specific size must be matched to the design, the manifold, the length of the individual circuits and the method of laying.
Why is the length of the circuit important?
The water loses temperature as it passes through the heating circuit, and the pipe itself creates hydraulic resistance.
If one circuit becomes too long, difficulties can arise in balancing and providing the required flow.
For larger rooms it is therefore usually more sensible to divide the area into several heating circuits, instead of making one overly long circuit.
What is the pipe spacing?
The spacing is the distance between two adjacent runs of the pipe.
A smaller spacing means a greater length of pipe per square metre. It can be used where the design requires greater heat output, but it should not be reduced arbitrarily.
In practice the spacing can even vary within a single room.
How is the pipe connected to the rest of the system?
When choosing, the following should be checked together:
- the pipe diameter;
- the system underlay;
- the Eurocones and the other connection elements;
- the manifold;
- the number of circuits;
- the required flow rate.
For example, a Ø16 mm pipe may be compatible with a system underlay intended for the Ø14–17 mm range.
Here you will also find the components needed to connect the heating circuits to the manifold, including Eurocone-type adapters.
What quantity of pipe is needed?
The quantity of pipe required cannot be determined from the area of the dwelling alone.
Consumption depends on:
- the actual heated area;
- the laying spacing;
- the number of circuits;
- the distance between the rooms and the manifold;
- the zones without pipes.
Two rooms of the same floor area may require a different quantity of pipe if a smaller spacing has been chosen in one of them.
What should you check before buying?
Check the size, the permitted operating parameters, the presence of an oxygen barrier, the length required and compatibility with the connection elements.
If you are not sure which size is suitable, we can guide you according to the area, the number of circuits, the manifold and the way the system will be built.
Frequently asked questions
1. Should I choose a 16 mm or 20 mm pipe?
The choice depends on the hydraulic sizing of the system. The pipe size should not be determined from the area alone.
2. Is it advisable to have a pipe joint under the screed?
Heating circuits are normally planned as continuous runs between the manifold and the return to it, without unnecessary hidden joints in the floor.
3. How is the number of metres of pipe required determined?
The quantity required is determined according to the area, the laying spacing, the lengths to the manifold and the distribution of the individual heating circuits.
4. Why is an oxygen barrier needed?
The oxygen barrier limits the penetration of oxygen through the pipe wall into the circulating water and thereby reduces the risk to the metal components of the heating system.
-