Castellated floor panels
The underfloor heating underlay is not simply a base on which the pipes are laid. It has a direct role in limiting downward heat losses and in building the heating circuits correctly. On system boards the formed studs fix the pipe and help the installation follow a set spacing.
When choosing, it is not only the thickness of the insulation that matters. You should check the permitted pipe diameter, the system height, the thermal resistance and the way the individual boards are joined.
Read more
What is the difference between the various underlays?
Here you will find solutions from INNOSTUD and HIRSCH POROZELL, including INNOSTUD 30 EPS 150, INNOSTUD 11, HIPS600 EPS150 TECHNIC 23+22, HIPS600 EPS150 TECHNIC 10+22 and NEW COMBITOP 30 mm with foil.
Besides thickness, the individual solutions also differ in design, which makes it possible to choose a suitable version according to the available floor height and the method of installation.
For example, INNOSTUD 30 EPS 150 has a nominal thickness of 30 mm and a total thickness including the formed elements of 49 mm. The effective board size is 1400x800 mm, the permitted pipe diameter is Ø14–17 mm, and the minimum spacing is 50 mm.
Why does the thickness of the insulation matter?
The heat from the pipes should be directed as much as possible towards the room, not towards the slab or the room below.
How much insulation is needed depends on the construction. Underfloor heating above a heated storey and underfloor heating above an unheated garage, for example, do not place the same demands on the thermal insulation layer.
The thickest version is not always the most suitable. In a renovation there is often a limit to the floor height, whereas in new construction a greater construction height can be planned in advance.
What do EPS and the density of the material mean?
EPS is expanded polystyrene, which is widely used for thermal insulation. For underfloor heating products it is important that the material is suitable for the load and the construction of the floor.
Designations such as EPS 150 give information about the class of the material and are one of the parameters that should be taken into account when choosing.
How do you match the underlay to the pipe?
Before ordering, check:
- the outside diameter of the pipe;
- what minimum and maximum spacing the underlay allows;
- the required construction height;
- whether a system board or smooth insulation will be used;
- how the pipes will be fixed.
On a system board such as INNOSTUD 30 the pipe is fixed between the formed elements. On smooth insulation you can use tacker clips and clamps.
How do you calculate the quantity required?
The quantity required is determined from the actual area that will be covered with insulation.
It is important to look at the effective area of the board or pack, not only the outer size of a single sheet. Some of the products are supplied in packs with a stated coverage area, which makes it easier to calculate the quantity required.
It is also advisable to allow a reserve for cuttings around walls, columns, shafts and other features of the room.
What should you compare between two underlays?
- thickness – determines part of the height of the floor build-up;
- thermal resistance – indicates the ability to limit the downward heat flow;
- permitted pipe diameter – must match the pipes chosen;
- spacing – determines the possible distances between the pipes;
- method of fixing – affects the installation;
- effective area – is needed for calculating the quantity correctly.
Frequently asked questions
1. Is every underlay suitable for a 16 mm pipe?
No. The range of diameters supported by the specific product should always be checked.
2. Does the underlay replace all the thermal insulation of the floor?
Not necessarily. This depends on the construction and the thermal resistance required. On some projects an additional insulation layer is provided under the system underlay.
3. Is a thicker underlay always better?
No. Besides the thermal insulation characteristics, the available height and the overall construction of the floor must be taken into account.
4. How much underlay should I order?
Calculate the area of the rooms that will be covered and compare it with the effective area of the specific pack. If you are choosing between several options, we can guide you according to the pipe and the construction of the floor.
-
insulation for underfloor heating INNOSTUD 30 EPS 150
Price: 82.09 € с ДДС
-
insulation for underfloor heating HIPS600 EPS150 TECHNIC 23+22
Price: 94.56 € с ДДС
-
insulation for underfloor heating NEW COMBITOP 30mm
Price: 112.24 € с ДДС
-
insulation for underfloor heating HIPS600 EPS150 TECHNIC 10+22
Price: 136.89 € с ДДС
-
insulation for underfloor heating INNOSTUD 11
Price: 145.17 € с ДДС



